• KOSASS
  • Contact us
  • E-Submission
ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS

Articles

Original Article

The Efficacy and Safety of Percutaneous Balloon Kyphoplasty in Compressive Vertebral Fracture: 5-Year Follow Up

Hun-Kyu Shin, Hwa-Jae Jeong, Eugene Kim, Jai Hyung Park, Se-Jin Park, Seok-Won Lee
Journal of Advanced Spine Surgery 2016;6(2):43-49.
Published online: December 31, 2016
Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea성균관대학교 의과대학 강북삼성병원 정형외과학교실
Corresponding author:  Hwa-Jae Jeong, Tel: +82-2-2001-2168, Fax: +82-2-2001-2176, 
Email: coolhkshin@hanmail.net
  • 28 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

Purpose
To evaluate long term efficacy of percutaneous balloon kyphoplasty for osteoporotic compressive vertebral fracture.
Materials and Methods
Percutaneous balloon kyphoplasty was performed to 52 vertebral bodies, for 42 patients with compression fracture from March 2003 to October 2007. During observation, 32 patients (39 vertebral bodies) were followed over 5 years except 8 patients (19.0%) who have expired. Pre operational, post operational and final observational radiologic evaluation (vertebral height, compression ratio, kyphotic angle) and clinic evaluation(VAS score) were checked. And correlation with bone cement leakage, fracture of adjacent vertebral body, gender, age, bone mineral density and medication was analyzed.
Result
Average age was 71.3 years old and average observation period was 74.3 months. Average interval from injury to operation was 24.1 days. Vertebral compression ratio recovered 29.7% to 17.4% (12.3%), kyphotic angle improved 11.6 degree to 9.0 degree (2.6 degree) and there was no significant change until final observation. VAS score got better 7.60 to 3.57 (4.03) after operation. Bone cement leakage occurred in 5 cases (12.8%) and fracture of adjacent vertebral body occurred in 10 cases (25.6%), there was no correlation between two groups (p=1.000). Fracture of adjacent vertebral body showed meaningful correlation with bone mineral density only.
Conclusion
Percutaneous balloon kyphoplasty relieve the pain after compression fracture of vertebral body and is safe and efficient procedure to correct sagittal deformity. After 5 year follow up, the effect of procedure was maintained clinically. Bone cement leakage did not increase risk of fracture of adjacent vertebral body which occurred frequently in low bone mineral density.

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

The Efficacy and Safety of Percutaneous Balloon Kyphoplasty in Compressive Vertebral Fracture: 5-Year Follow Up
J Adv Spine Surg. 2016;6(2):43-49.   Published online December 31, 2016
Download Citation
Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
  • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
  • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
Include:
  • Citation for the content below
The Efficacy and Safety of Percutaneous Balloon Kyphoplasty in Compressive Vertebral Fracture: 5-Year Follow Up
J Adv Spine Surg. 2016;6(2):43-49.   Published online December 31, 2016
Close
TOP